Red Hat CLUSTER SUITE 4.7 DM MULTIPATH Guida di Installazione Pagina 156

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 188
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 155
140 Appendix A. Supplementary Hardware Information
Figure A-1. Single-controller RAID Array Connected to Single-initiator Fibre Chan-
nel Interconnects
The external RAID array must have a separate SCSI channel for each cluster node. In
clusters with more than two nodes, connect each node to the SCSI channel on the RAID
array, using a single-initiator SCSI bus as shown in Figure A-1.
To connect multiple cluster nodes to the same host port on the RAID array, use a Fibre
Channel hub or switch. In this case, each host bus adapter is connected to the hub or
switch, and the hub or switch is connected to a host port on the RAID controller.
A Fibre Channel hub or switch is also required with a dual-controller RAID array with two
host ports on each controller. This configuration is shown in Figure A-2. Additional cluster
nodes may be connected to either Fibre Channel hub or switch shown in the diagram. Some
RAID arrays include a built-in hub so that each host port is already connected to each of
the internal RAID controllers. In this case, an additional external hub or switch may not be
needed.
Vedere la pagina 155
1 2 ... 151 152 153 154 155 156 157 158 159 160 161 ... 187 188

Commenti su questo manuale

Nessun commento