Failed to start LSB: Bring up/down networking.
Unit network.service entered failed state.
Applies to: Red Hat Enterprise Linux 7.0
Cause: In the network.service script, nmcli cannot get the network interface state
information for the first time. The retry is successful.
Workaround: This error can be ignored as there is no functionality loss.
Unable to move the OpenManage Server Administrator
icon anywhere on the desktop
Description: You are unable to move the OpenManage Server Administrator icon anywhere on
the desktop. Error while copying message is displayed.
Applies to: Red Hat Enterprise Linux 7.0
Cause: Hard linked .desktop files do not have source files information populated
appropriately.
Workaround: This error can be ignored as there is no functionality loss.
ras-mc-ctl command displays DIMM labels related error
message
Description: When you run the command ras-mc-ctl --print-labels, the system displays the
error No dimm labels for Dell Inc.
Applies to: Red Hat Enterprise Linux 7.0
Cause: rasdaemon is unable to get the DIMMs details from the SQLite datebase. Also,
rasdaemo cannot guess the DIMMs label using the dmidecode for the new
memory controllers.
Workaround: This error can be ignored as there is no functionality loss.