3 – Managing Fabrics
Zoning a Fabric
59056-00 Rev. B 3-17
D
MaxTotalMembers is 2000. The maximum number of total zone and alias
members that can be configured on the switch. This will be enforced during
the configuration of zoning and during a zoning database merge from the
fabric. Aliases are considered zone members since they can be added to a
zone just like a normal zone member.
MaxZonesInZoneSets is 1000. The maximum number of zone linkages to
zonesets that can be configured on the switch. This will be enforced during
the configuration of zoning and during a zoning database merge from the
fabric. Every time a zone is added to a zoneset this constitutes a linkage.
MaxMembersPerZone is 2000. The maximum number of zone members
that can be added to any zone on the switch. This will be enforced during the
configuration of zoning and during a zoning database merge from the fabric.
Aliases are considered zone members when added to a zone.
MaxMembersPerAlias is 2000. The maximum number of zone members
that can be added to any alias on the switch. This will be enforced during the
configuration of zoning and during a zoning database merge from the fabric.
3.4.1.5
Zoning Configuration
You can set the FC-SW-2 Auto Save and Default Visibility zoning configuration
parameters using SANbox Manager. The Auto Save parameter determines
whether changes to the active zone set that a switch receives from another switch
in the fabric will be saved to permanent memory on that switch. The Default
Visibility parameter permits or prohibits communication among ports/devices
when there is no active zone set. Refer to ”Using the Zoning Config Dialog” on
page 3-17 for information about zoning configuration using SANbox Manager.
3.4.2
Using the Zoning Config Dialog
Use the Zoning Config dialog to change the Auto Save and Default Visibility
configuration parameters. In the faceplate display, open the Zoning menu and
select Edit Zoning Config to open the Zoning Config dialog shown in Figure 3-5.
After making changes, click the OK button to put the new values into effect.
Figure 3-5. Zoning Config Dialog
Commenti su questo manuale